Urnex Complete Cafe - Cold Brew Coffee Equipment Sanitizer

Urnex Complete Cafe - Cold Brew Coffee Equipment Sanitizer
Brand: Keg Outlet
Part Number: 15-CPCF32
Price: $52.99 to $89.99

Qty
Safe and Secure Shopping at Keg Outlet

Complete Cafe by Urnex

Complete Cafe is an EPA-registered sanitizer that is designed for use on and around coffee, tea, and other café-style equipment. Packaged in a dual-chamber 1 liter bottle that features a built-in measuring device, allowing for easy measurment and portioning and PPM control.

Complete Café should not be used as a hand sanitizer.

Food Contact Sanitizing Performance
This product is an effective food contact sanitizer in 1 minute at 1 oz per 4 gal of 500 ppm hard water on hard, non-porous surfaces: Escherichia coli, Salmonella enterica, Staphylococcus aureus.

Directions For Use
It is a violation of Federal Law to use this product in a manner inconsistent with its labeling. Before using this product, food products and packaging materials must be removed from the room or carefully protected.

Food Contact Sanitizing Directions
Prior to application, remove gross food particles and soil by a pre-flush or pre-scrape and when necessary, presoak. Then thoroughly wash or flush objects with a good detergent or compatible cleaner, followed by a potable water rinse before applications of the sanitizing solution.

Food Contact Sanitizing Performance Directions (Regulated by 40 CFR 180.940 (a)(c)
Immerse pre-cleaned glassware, dishes, silverware, cooking utensils and other similar size food processing equipment in a solution of 1-2 oz of this product per 4 gal of water (200-400 ppm active quat) (or equivalent use dilution) for at least 1 minute. Allow sanitized surfaces to adequately drain before contact with food. Do not rinse. For articles too large for immersing, apply a use solution of 1-2 oz of this product per 4 gal of water (200-400 ppm active quat) (or equivalents use dilution) to sanitize hard, non-porous food contact surfaces with a brush, cloth, mop sponge, auto scrubber, or mechanical spray device. For spray applications, spray 6-8 inches from surface. Do not breathe spray. Surfaces must remain wet for at least 1 minute. Allow sanitized surfaces to adequately drain before contact with food. Do not rinse. Prepare a fresh solution daily or when visibly dirty. For mechanical applications, use solution must not be reused for sanitizing applications.

Beverage Dispensing and Sanitary Filling Equipment Sanitizer Directions
For sanitizing hard, non-porous bottling or pre-mix dispensing equipment and bottles or cans in the final rinse application. This product is to be proportioned into the final rinse water line of the container washer or rinser. Fill equipment with a solution of 1-2 oz of this product per 4 gal of water (200-400 ppm active quat) (or equivalent use dilution). Surfaces must remain wet for at least 1 minute or until operations resume at which time the sanitizing solution must be drained from the system. Allow sanitized surfaces to adequately drain before contact with liquid. Do not rinse.

Sanitization of Interior Hard, Non-Porous Surfaces of Ice Machines
Sanitization must occur after initial installation, after the machine is serviced and periodically during its use. 1. Shut off incoming water line to machine and turn off refrigeration. 2. Wash with a compatible detergent and rinse with potable water before sanitizing (Note: Use this direction only if applicable). 3. Apply a solution of 1-2 oz of this product per 4 gal of water (200-400 ppm active quat) (or equivalent use dilution) by mechanical spray, direct pouring, or by recirculating through the system. 4. Allow surfaces to remain wet or solution to remain in equipment for at least 1 minute. Drain thoroughly before reuse and allow sanitized surfaces to adequately drain before contact with liquid. 5. Return machine to normal operation.

FOR USE AS A GENERAL CLEANER
Apply use solution of 1 oz of this product per 4 gal of water to hard, non-porous surfaces. Allow to air dry. For heavy-duty use, add 2 oz of this product per 4 gal to clean hard, non-porous surfaces.

STORAGE AND DISPOSAL
Do no contaminate water, food, or feed by storage and disposal. Pesticide storage: Store only in original container. Keep this product under locked storage sufficient to make it inaccessible to children of persons unfamiliar with its proper use. Pesticide disposal: Pesticide wastes are acutely hazardous. Improper disposal of excess pesticide, spray mixture or rinsate is a violation of Federal Law. If these wastes cannot be disposed of by use according to label instructions, contact your State Pesticide or Environmental Control Agency, or the Hazardous Waste Representative at the nearest EPA Regional Office for guidance. Container Handling: Non-Refillable Container. Do not reuse or refill this container. Triple rinse container promptly after emptying. Triple rinse as follows: Fill the container ¼ full with water and recap. Shake for 10 seconds. Drain for 10 seconds after the flow begins to drip. Follow Pesticide Disposal instructions for rinsate disposal. Repeat this procedure two more times. Then offer for recycling if available or puncture and dispose of in a sanitary landfill, or by incineration.

Scroll to view product options.

Item / Part # Quantity Price
Urnex Complete Cafe - Cold Brew Coffee Equipment Sanitizer
15-CPCF32
1 liter $52.99 Add to Cart
Urnex Complete Cafe (2 Bottles) - Cold Brew Coffee Equipment Sanitizer
15-CPCF32x2
2 liters $89.99 Add to Cart

Scroll to view product options.

Help other customers

Be the first to review this item

FAQs Urnex Complete Cafe - Cold Brew Coffee Equipment Sanitizer

    Have a question about this product?

    Others probably do too! Ask a question and we'll follow up with you individually. If your question is added to our FAQ section, it will remain anonymous.

    Be the First to Ask a Question

    Other Resources

    Replacement Parts:

    Fits These Applications:

    Year Make Model SubModel Engine Transmission Drive